NEC SL1000 Programming Manual page 450

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000
Item
No.
10
Wink/Delay Signal Detect Timeout Se-
lection
To specify a maximum time, in seconds, for
receiving an acknowledgment signal from
a distant system before sending a busy
tone.
11
Disconnect Recognition Time Selection
Specify the minimum time before a discon-
nected circuit can be accessed again.
12
Automatic Release Signal Detection Se-
Program
lection
Specify the signal detection time for
release of a Tie Line after a disconnect
81
signal is received from the distant CO or
PBX.
13
Pause Time Selection
14
Hookflash Time Selection 1
15
Hookflash Time Selection 2
Conditions
None
Feature Cross Reference
None
2-430
I
e t
m
0 = ∞ (Nolimit)
1~15
(1~15 sec)
1~15
(0.1~1.5 sec)
(0 = No Setting)
1~14
(50~700ms)
15 = ∞ (Nolimit)
(0 = No Setting)
1~15
(500~7500ms)
0 = 20ms
1 = 40ms
2 = 60ms
3 = 80ms
4 = 100ms
5 = 140ms
6 = 160ms
7 = 200ms
8 = 400ms
9 = 600ms
10 = 800ms
11 = 1.0 second
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
0 = 20ms
1 = 40ms
2 = 60ms
3 = 80ms
4 = 100ms
5 = 140ms
6 = 160ms
7 = 200ms
8 = 400ms
9 = 600ms
10 = 800ms
11 = 1.0 second
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
n I
p
t u
D
a
a t
Program 81 : Basic Hardware Setup for Trunk
Issue 0.1
D
e
a f
u
t l
7 (7 sec)
3
(0.3 sec)
7
(350 ms)
6
(3000 ms)
9
(600 ms)
14
(3.0 sec)