Description
Use Program 90-12 : System Alarm Output to set the options for the alarm report. This program has
Program
six separate menu options. Define the output port to be used as the output for system alarm report and
set the system alarm options. The system can have up to 50 reports.
90
Input Data
Item No.
01
Conditions
None
Feature Cross Reference
None
2-506
Program 90 : Maintenance Program
Item
Output Port Type
Indicate the type of connection used for the
System Alarms. The baud rate for the COM port
should be set in Program 10-21-02.
90-12 : System Alarm Output
Input Data
0 = No Setting
1~4 = Not Used
5 = Compact Flash
Program 90 : Maintenance Program
Issue 0.1
Default
0