3. Initiate a power on reset with an NCK general reset (NCK commissioning switch: position
"1"). See:
References:
Commissioning Manual IBN CNC: NCK, PLC, drive; Chapter: General tips > Separate NCK
and PLC general reset > NCK general reset
4. Download the NC archive created under Point 1 into the NCU again.
Operating area: "Commissioning" > "ETC" key > "Commissioning archive" > "Read-in
commissioning archive" > "OK"
Note
Several loaded compile cycles
If several compile cycles are loaded in the control, when deleting a compile cycle according
to the process described above, the other compile cycles remain unchanged.
Efficient memory usage
To use the memory resources in the NCK as efficiently as possible, you should only load the
compile cycles (ELF files) that are actually required into the machine.
13.9
Data lists
13.9.1
Machine data
13.9.1.1
NC-specific machine data
Number
Identifier: $MN_
60900 + i
CC_ACTIV_IN_CHAN_XXXX[n]
with:
with:
i = 0, 1, 2,
XXXX = function code
3, ...
n = 0 or 1
Special functions
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
TE01: Installation and activation of loadable compile cycles
Description
n = 0:
Activating the technology function in NC channels
n = 1:
Additional functions within the technology function
13.9 Data lists
559