TE8: Cycle-independent path-synchronous switching signal output - 840D sl only
20.5 Function-specific alarm texts
Programming example
Programming
DEF REAL PATH_DISTANCE_ON = 0.5
DEF REAL PATH_DISTANCE_OFF = 1.0
CC_FASTON_CONT (PATH_DISTANCE_ON, PATH_DISTANCE_OFF)
Changing parameters
The parameters for the CC_FASTON_CONT( ) procedure can be modified at any time during
the execution of the part program. For this, the procedure call must be specified again with the
new parameter values.
Reset response
A reset (NC RESET or end of program) deactivates the function.
20.4.3
Deactivation (CC_FASTOFF)
Syntax
CC_FASTOFF
CC_FASTOFF is a procedure call and must therefore be programmed in a dedicated part
program block.
Functionality
The CC_FASTOFF procedure call deactivates the "Cycle independent, path synchronized
switching signal output" function.
20.5
Function-specific alarm texts
For details of the procedure for creating function-specific alarm texts, see Section "Creating
alarm texts (Page 555)".
740
Comment
; Length* of the stretch section with
machining = 0.5
; Length* of the stretch section
without machining = 1.0
; Activating path
length-related
switching signal out-
put.
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
Special functions