TE01: Installation and activation of loadable compile cycles
13.4 Activating the technological functions in the NCK
13.3
Software version of a compile cycle
The SW version of a compile cycle is displayed under:
HMI Advanced:
Diagnosis > Service Display > Version > NCU Version
Display (excerpt)
-------------------------------------------
CC Interface Version:
@NCKOPI . . . .
Loaded Compile Cycles:
Identifier > < Version > < Generation Data >
<
CC start address
_N_<
Code=<
-------------------------------------------
Example:
_N_CLC407IF003001_ELF corresponds to software version 4.7
Note
The display of code and data range start addresses of a compile cycle are provided for
diagnostics purposes only and have no significance in normal operation.
13.4
Activating the technological functions in the NCK
Requirement
The corresponding option must be enabled before activating a technology function as
described below.
If the option data has not been set, the following alarm appears every time the NCK boots and
the technology function will not be activated:
Alarm 7202 "XXX_ELF_option_bit_missing: <
Function-specific machine data
Each technology function loaded by compile cycle creates a function-specific global NCK
machine data within the range of numbers from 60900 to 60999 in accordance with the
following pattern:
$MN_CC_ACTIVE_IN_CHAN_<
Example:
554
Identifier ><Version>IF< 1st digit >< 2nd digit >_ELF . . .
Address > Data=< Address > . . .
Bit number >"
identifier >[n], with n = 0, 1
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
Special functions