Closed-Loop Control Gain (Clc_Gain) - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

In the case of a re-orientation (rotation) of the compensation vector, it is also necessary to note
the ratio between the programmed traversing path and the configured dynamic response of
the direction axes. The ratio should be chosen such that the programmed traversing path is
not traversed in one or a small number of interpolation cycles, due to the dynamic response
of the axis. This causes heavy loads on the machine and, in certain circumstances, may trigger
axial alarms and abort part program execution.
Example
Rotation of the compensation vector and thus the machining head through 90°:
● Initial orientation: Parallel to coordinate axis X
● Target orientation: Parallel to coordinate axis Y
Bad programming of re-orientation:
● [1, 0, 0] → [0, 1, 0]
Good programming of re-orientation:
● [100, 0, 0] → [0, 100, 0]
Rotation of the workpiece coordinate system
As described above, the compensation vector always refers to the basic coordinate system
(machine coordinate system). If the workpiece coordinate system (rotation, mirroring) is
transformed to machine a workpiece in such a way that the coordinate axes of both coordinate
systems are no longer parallel with the same orientation, a corresponding transformation must
be carried out for the compensation vector.
Unequal orientation
If the workpiece coordinate system is transformed such that the coordinate axes of the basic
and workpiece coordinate systems are no longer parallel with the same orientation, it is the
sole responsibility of the user to ensure that an appropriate transformation of the
compensation vector is carried out.
15.6.2

Closed-loop control gain (CLC_GAIN)

Syntax
CLC_GAIN =
Factor
● Format: Real
● Range of values: y 0.0
CLC_GAIN is an NC address and can therefore be written together with other instructions in
a part program block.
When a negative factor is programmed, the absolute value is used without an alarm output.
Special functions
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
CAUTION
Factor
TE1: Clearance control - 840D sl only
15.6 Programming
585

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents