Limiting The Control Range (Clc_Lim) - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Figure 15-11 Response of the CLC offset vector when CLC_GAIN=0.0
Reset
Within a part program, a modified gain factor must be reset by means of explicitly programming
CLC_GAIN=1.0.
RESET behavior
CLC_GAIN=1.0 becomes effective after a power on reset, NC RESET or end of program.
15.6.3

Limiting the control range (CLC_LIM)

Syntax
CLC_LIM(
Lower limit , upper limit
Format and value range as machine data:
● MD62505 $MC_CLC_SENSOR_LOWER_LIMIT[n] (lower clearance control motion limit)
● MD62506 $MC_CLC_SENSOR_UPPER_LIMIT[n] (upper clearance control motion limit)
CLC_LIM(...) is a procedure call and must therefore be programmed in a dedicated part
program block.
Special functions
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
lower limit , upper limit )
TE1: Clearance control - 840D sl only
15.6 Programming
587