TE02: Simulation of Compile Cycles (only HMI Advanced)
14.2 OEM transformations
4. Close the HMI application.
5. Launch the HMI application.
6. In the directory for the manufacturer cycles, create the file "TRAORI.SPF" with the following
content:
PROC TRAORI(INT II)
RET
7. In the directory for the manufacturer cycles, create the file "TRACON.SPF" with the
following content:
PROC TRACON(INT II)
RET
Note
The "TRAORI.SPF" and "TRACON.SPF" manufacturer cycles created under 6. and 7. must
not be loaded onto the NC.
8. Start the simulation.
9. Run a data comparison for the cycles after the simulation has started up:
HMI Advanced: Data comparison > Compare cycles
Note
At least the password for protection level 3 "End user: Service" is needed for the data
comparison.
562
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
Special functions