SL1000/SL1100
• Since making changes in PRG 11-01 does not automatically make any other changes in any other
program, changing the number plan after the system is in operation may cause problems in the
following programs:
11-02
11-04
11-06
11-07
• Any feature which requires dialing a code or extension number can be affected.
• When the system searches the Dial Extension Analyze Table (PRG 11-20-01), the system uses
prefix searching, giving the lower table number the higher priority. For example, the user programs
F
211 in table 1 and 2113 in table 2, then dials 2113, the system selects table 1.
11-01-01 = Dial 3
31 Digit 4 = (9) Dial Extension Analyze Table
11-20-01 Table 1 = Dial 310
11-20-02 Table 1 = Intercom
11-01-01 = Dial 3
31 Digit 6 = (9) Dial Extension Analyze Table
11-20-01 Table 1 = Dial 31000
11-20-02 Table 1 = Intercom
Default Settings
Extensions and Virtuals are numbered in the following order:
PRG 11-02-01 and PRG 11-04-01
• Physical Extensions:
- Extn Port 1 = 200 ~ Extn Port 128 = 327
• Virtual Extensions:
- All VE Ports = No setting
System Availability
Terminals
All Stations
Required Component(s)
None
1-250
PRG 11-01 Type 2
(Extension Number)
11-08
15-12
11-17
16-01-01
15-01-01
15-14
15-07
21-11
Example for 310X
10s Group
(4-digit)
Example for 31000X
1000s Group
(6-digit)
22-11
11-10
25-06
11-11
30-03
11-12
11-13
Example for 3100X
11-01-01 = Dial 3
31 Digit 5 = (9) Dial Extension Analyze Table
11-20-01 Table 1 = Dial 3100
11-20-02 Table 1 = Intercom
Example for 310000X
10,000s Group
11-01-01 = Dial 3
31 Digit 7 = (9) Dial Extension Analyze Table
11-20-01 Table 1 = Dial 310000
11-20-02 Table 1 = Intercom
ISSUE 2.0
PRG 11-01 Type 1
(Service Codes)
11-14
21-11
11-15
30-03
15-07
15-14
100s Group
(5-digit)
(7-digit)
Flexible System Numbering