• After finishing VRS message, destination person can start monitoring of inspection terminal. Also by
dialing
*
from outside it is possible to have a two-way conversation.
If you dial
the message stops the message from being played and you must dial
speech path.
When using Analog trunks, the destination person must dial
the caller.
• If outgoing call restriction is set, the emergency call number must be pre-registered in the restriction
allow table, then emergency call can go through. Also even all trunk are busy, the call has high
priority and can go out.
• If destination does not answer the emergency call, the system repeatedly places the call for the
number of times specified in PRG 20-45-07.
• Maximum of 6 extensions can be set as Remote Inspection terminals.
S
• If all VRS channels are busy, tone will be provided instead of VRS message, such as for inspection
message or for destination message.
• If VRS message itself is not recorded, tone will be provided.
Emergency call destination MUST be set considering this feature's purpose.
• The emergency number dialed does not follow ARS settings.
If PRG 13-01-01 is set to Trunk the system uses command PRG 13-05 to route the emergency call.
If PRG 13-01-01 is set to ICM the system uses command PRG 14-06 to route the emergency call.
• The VRS allows you to record up to 100 VRS messages (001-100) when using the compact flash
card. If you are using the built in VRS, without the compact flash, then you can only record message
1 (001).
Emergency Call 1
Emergency calls when "Security Sensor" or "Remote Inspection" performed, SMDR can record these
call class as follows.
• Security Sensor: SAD
• Remote Inspection: WAD
If the system is using the built in VRS for messages and a message is being played over the paging system
(Internal or External), then the outside emergency call will not play a message; it will play warning tone.
The built in VRS only has 1 channel and can either play the message over the paging system or play the
message to the outside caller; it cannot do both.
Emergency Call 2
Emergency calls when "Security Sensor" or "Remote Inspection" performed, alarm report can record
these alarm and alarm display terminal indicates following on LCD.
• Security Sensor: 31: Sensor Dial
• Remote Inspection: 32: Confirm dial
Recording Emergency Call
By setting PRG 90-20-11 (1; Report), Emergency calls can be recorded on security report.
• Maximum of 50 records can be saved.
Default Settings