Specifications - LG MULTI V ARNU07GTUA4 Engineering Product Data Book

Hide thumbs Also See for MULTI V ARNU07GTUA4:
Table of Contents

Advertisement

Indoor unit

2. Specifications

Type
Model
Cooling Capacity
Heating Capacity
Casing
Dimensions(WxHxD) Body
Rows x Columns x FPI
Coil
Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H / M / L)
(High Mode-factory set)
Fan
External Static Pressure mmAq(Pa)
Air Flow Rate(H / M / L)
(Standard Mode)
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
Pipe Connections Gas Side
Drain Pipe(Internal Dia.)
Net Weight
Body
Noise Level(Sound Pressure, 1.5m, H / M / L)
Power Supply
Refrigerant Control
Transmission Cable
Notes:
1. Capacities are based on the following conditions:
Cooling
• Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
Heating
• Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. Wiring cable size must comply with the applicable local and national codes. And "Electric characteristics"
chapter should be considered for electrical work and design. Especially the power cable and circuit breaker
should be selected in accordance with that.
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 50Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
2 _
Ceiling Concealed Duct(Middle Static)
Unit
ARNU07GM1A4
kW
2.2
kcal/h
1,900
Btu/h
7,500
kW
2.5
kcal/h
2,200
Btu/h
8,500
Galvanized Steel Plate
mm
900 × 270 × 700
inch
35-7/16 x 10-5/8 x 27-9/16 35-7/16 x 10-5/8 x 27-9/16 35-7/16 x 10-5/8 x 27-9/16
2 x 13 x 18
m
2
0.21
Sirocco Fan
W
136 x 1
A
1.6
CMM
9.0 / 7.5 / 6.0
cfm
318 / 265 / 212
6(59)
CMM
9.0 / 7.5 / 6.0
cfm
318 / 265 / 212
2.5(25)
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
-
Fuse
mm(inch)
Ø6.35(1/4)
mm(inch)
Ø12.7(1/2)
mm(inch)
25(1)
kg(lbs)
25.5(56)
dB(A)
26 / 24 / 23
1, 220-240, 50
Ø, V, Hz
1, 220, 60
EEV
mm
2
CVV-SB 1.0~1.5 x 2C
Ceiling Concealed Duct - Middle Static
ARNU09GM1A4
2.8
2,400
9,600
3.2
2,800
10,900
Galvanized Steel Plate
900 × 270 × 700
2 x 13 x 18
0.21
Sirocco Fan
136 x 1
1.6
9.5 / 7.5 / 6.0
336 / 265 / 212
6(59)
9.5 / 7.5 / 6.0
336 / 265 / 212
2.5(25)
Direct
BLDC
Foamed polystrene
-
Fuse
Ø6.35(1/4)
Ø12.7(1/2)
25(1)
25.5(56)
27 / 25 / 23
1, 220-240, 50
1, 220, 60
EEV
CVV-SB 1.0~1.5 x 2C
ARNU12GM1A4
3.6
3,100
12,300
4.0
3,400
13,600
Galvanized Steel Plate
900 × 270 × 700
2 x 13 x 18
0.21
Sirocco Fan
136 x 1
1.6
11.0 / 9.0 / 7.0
388 / 318 / 247
6(59)
11.0 / 9.0 / 7.0
388 / 318 / 247
2.5(25)
Direct
BLDC
Foamed polystrene
-
Fuse
Ø6.35(1/4)
Ø12.7(1/2)
25(1)
25.5(56)
27 / 25 / 23
1, 220-240, 50
1, 220, 60
EEV
CVV-SB 1.0~1.5 x 2C
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi v arnu09gtua4Multi v arnu12gtua4Multi v arnu18gtta4Multi v arnu24gtta4Multi v arnu09gtla4Multi v arnu12gtla4 ... Show all

Table of Contents