10. Installation
10.4 Installation of Decoration Panel (Panel Type)
The decoration panel has its installation
direction.
1. Open the air outlet vane, and extract side covers.
2. Remove the air inlet panel from the decoration panel.
3. Hook decoration panel to indoor unit, using hooks attached at the backside of both side of decoration
panel.
4. Arrange wires not to get caught between decoration panel and indoor unit.
5. Screw 7 fixing screws. (7,9,12kBtu : 6 screws)
6. Connect the vane motor connector ,display connector and air inlet panel connector.
7. Install the air inlet panel (including the air filter) and side covers.
Air conditioner unit
Robot kit
Decorative panel
Air outlet vane
CAUTION
Install certainly the
decoration panel.
Cool air leakage caus-
es sweating.
⇨ Waterdrops fall.
Good example
Air conditioner
unit
Decorative panel
Fit the insulator (this part) and
be careful for cool air leakage
Before installing the decoration panel,
always remove the paper template.
Decorative panel
fixing screws
(hexagon M6 screws)
(tightening about 20mm)
Air inlet panel
Bad example
Cool air leakage
(no good)
Ceiling
board
Ceiling Cassette 1-Way
Mesh
Control box cover
Side cover
Air conditioner
unit
Ceiling
board
Decorative panel