Cfm Loopback Test - D-Link DGS-3130 Series Web Ui Reference Manual

Hide thumbs Also See for DGS-3130 Series:
Table of Contents

Advertisement

DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
After clicking the Show Detail button, the following page will appear.
Click the Back button to return to the previous window.

CFM Loopback Test

This window is used to display and configure the CFM loopback test settings.
To view the following window, click OAM > CFM > CFM Loopback Test, as shown below:
The fields that can be configured are described below:
Parameter
MAC Address
Remote MEPID
MEPID
MA Name
Domain Name
LBMs Number
LBM Payload Length
LBM Payload Pattern
Figure 10-13 CFM Port Settings (View Detail) Window
Figure 10-14 CFM Loopback Test Window
Description
Select and enter the destination MAC address here.
Select and enter the remote MEP ID here. The range is from 1 to 8191.
Enter the MEP ID that will initiate the loopback test here. The range is from 1 to
8191.
Enter the MA name here. This name can be up to 22 characters long.
Enter the MD name here. This name can be up to 22 characters long.
Enter the number of LBMs to be sent here. The range is from 1 to 65535. By
default, this value is 4.
Select and enter the payload length of the LBM to be sent here. The range is
from 0 to1500. By default, this value is 0.
Select and enter the LBM payload pattern here. This specifies an arbitrary
amount of data to be included in a Data TLV, along with an indication whether
the Data TLV is to be included. This string can be up to 1500 characters long.
No spaces are allowed.