4-6-7 Trigger counter reset input
TRIGGER IN (X6)
SELECT 0-2 IN (No.20-22)
D0 IN (No.3)
SET IN (No.2)
READY OUT (Y6)
LASING OUT (Y7)
LASING END OUT (Y8)
SET OK OUT (No.36)
Item
Time
T1
10 ms or more
T2
20 to 510 ms
T3
0.5 ms or more
T4
0 ms or more
T5
―
*1 : To reset the counter, set SELECT 0 IN to SELECT 2 IN (No.20-22) as follows.
Number input target
Counter type to reset
*2 : Set D0 IN (No.3) to specify the counter type to reset.
• When D0 IN (No.3) is OFF: Both Trigger count and Error count are reset.
• When D0 IN (No.3) is ON: Error count is reset.
118
T1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
T2
OFF
ON
OFF
Remarks
Keep the ON status for 10 ms or more.
One-shot output. Set the output time on the environment setting screen. There is a small
margin of error for the setting value.
After a lapse of 0.5ms or more from specifying D0 IN (No.3), turn on SET IN (No.2).
Keep the input until SET OK OUT (No.36) turns on.
Setup time of the laser welding machine to start the lasing operation.
SELECT 0 IN (No. 20)
ON
ME-VLW1N-SM-1
T1
*1
*2
T3
T4
T5
T2
SELECT 1 IN (No. 21)
OFF
T2
SELECT 2 IN (No. 22)
OFF