4-5-3 Connecting sample of shutter close output

Laser welding machine
Shutter close output terminal
1. SHUTTER CLOSE OUT COM.
2. SHUTTER CLOSE 1 OUT
3. SHUTTER CLOSE 2 OUT
I/O terminal
X10: SHUTTER IN
X11: SHUTTER ENABLE IN
Y10: SHUTTER OPEN OUT
Interlock connector
INTERLOCK 1 IN
INTERLOCK 2 IN
FEEDBACK 1,2 OUT
*1 : It is recommended to connect the safety devices such as safety PLC for the connection with shutter close output
terminal and interlock connectors.
*2 : Do not use SHUTTER OPEN OUT (Y10) for the safety confirmation purpose. To monitor the shutter operation for the
safety control system, use SHUTTER CLOSE 1 OUT and SHUTTER CLOSE 2 OUT (Shutter close output terminal
No.2, 3).
110
PLC, etc.
OUTPUT
OUTPUT
*2
INPUT
Peripheral devices
(external shutter, door, etc.)
Emergency stop switch
ME-VLW1N-SM-1
Safety PLC, etc. *1
NPN connection: 0 V
PNP connection: 24 V
SHUTTER CLOSE MONITOR
SHUTTER CLOSE MONITOR
INTERLOCK 1 OUTPUT
INTERLOCK 2 OUTPUT
INTERLOCK MONITOR
INPUT/OUTPUT for
peripheral devices
EMERGENCY STOP INPUT