Panasonic VL-W1-N Series Setup And Maintenance Manual page 170

Laser welding machine
Table of Contents

Advertisement

ERROR
CODE
Invalid input of lasing trigger because
E800
trigger ready output is off.
LASER STOP 1 IN on I/O terminal is
E811
disconnected.
E812
Laser power is out of threshold.
* : If the error persists after restart of the laser welding machine, contact our sales office or representatives.
170
Description
ME-VLW1N-SM-1
Measures *
• Make sure that the trigger ready output is ON and input to
the TRIGGER IN terminal.
• Do not input the lasing trigger while the lasing output is
ON.
• Check for any malfunctions of the switch/sensor connected
to the TRIGGER IN on the I/O terminal.
• Check wiring of I/O or communication port to the external
control devices.
• Check the procedures and operation logic of trigger
control.
• Check wiring of LASER STOP 1A/1B IN on the I/O
terminal.
• Check the status of the safety equipment connected to the
LASER STOP terminals.
• Confirm operation logic of the connected device.
• Check the setting value of thresholds.
• If there is a decrease in lasing quality, check the output
power.