Dip Switch Setting - Panasonic VL-W1-N Series Setup And Maintenance Manual

Laser welding machine
Table of Contents

Advertisement

3-5-1 DIP switch setting

Set the operational options for the external control with the DIP switch equipped on the controller rear side.
• The initial setting of all DIP switches is OFF.
• Turn OFF the power at DIP switch setting.
• For the details on DIP switch, refer to "3-5-1 DIP switch setting" (P.78).
1.
Turn OFF the power of laser welding machine.
2.
Remove the DIP switch cover on the rear of
the controller.
3.
With DIP switch No. 2, select the control method, I/O or command
for some specific operations.
DIP switch No. 2
ON
OFF (initial setting)
4.
With DIP switch No. 5, select the setting method of the remote
mode.
DIP switch No. 5
ON
OFF(initial setting)
• When DIP switch No. 5 is ON, the remote switch on the controller is not available.
78
Control method for specific operations
Control by serial communication commands for the
following operations
• Laser pumping (LSR)
• Shutter open/close (SHT)
• Guide laser (GID)
• Laser radiation for measurement (SPT)
Control by I/O for the following operations
• Laser power supply (Laser pumping)
• Shutter open/close
• Guide laser radiation
Setting method of remote mode
Use the input signal of X5 "REMOTE IN" on I/O terminal.
Use the remote switch on the front of the controller.
ME-VLW1N-SM-1
ON
OFF
VL-W1500-N, VL-W1506-N
Rear of controller
DIP switch
VL-W1A00-N, VL-W1A06-N