Husqvarna DXR 95 Operator's Manual page 46

Table of Contents

Advertisement

Available languages

Available languages

Cooling kit (DXR 145)
The cooling kit (A) is used in high ambient temperatures.
A hose from an external air compressor is connected
to the product. The airflow is used to keep the product
cool. The cooling kit prevents too high temperature in
Operating temperatures for the
the product. Refer to
cooling and heat kit on page 145 . Connect the hose to
the product before you start the product in high ambient
temperatures. If the airflow is to low, close the rear
nozzles (B) to make sure that the electrical enclosure
does not become too hot. The cooling kit for (DXR 145)
have a air filter and a automatic system (C) for air moist
separation. This system will keep moist air away from
the electrical enclosure. Make sure that the air filter is
replaced regularly.
Cooling kit (DXR 275, DXR 305, DXR 315)
The cooling kit (A) is used in high ambient temperatures.
A hose from an external air compressor is connected
to the product. The airflow is used to keep the product
cool. The cooling kit prevents too high temperature in
Operating temperatures for the
the product. Refer to
cooling and heat kit on page 145 .
A
46
A
C
B
Heat protection kit (DXR 145)
The heat protection kit is used in very high ambient
Operating temperatures for the
temperatures. Refer to
cooling and heat kit on page 145 . The heat protection
kit is an accessory that can be installed by an approved
dealer.
The heat protection kit for the product includes steel
outrigger feet (A), steel caterpillar tracks (B), heat
resistant hoses (C) for cylinder four and fire resistant
hydraulic oil (D).
The breaker heat protection kit (E) includes heat-
resistant hoses, cooling extension to the breaker, and
a long working tool.
The air flow to the installed tool on the product can be
adjusted with an adjustable valve (F) on arm 1. Keep
the airflow valve open 6-turns out of 7 when the product
start. If the airflow blows too much dust at the tool, lower
the airflow.
C
F
E
Heat protection kit (DXR 275, DXR 305, DXR
315 and SB 202/302)
The heat protection kit is used in very high local
Operating temperatures for the
temperatures. Refer to
cooling and heat kit on page 145 .
The heat protection kit for the product includes steel
outrigger feet (A), steel caterpillar tracks (B), heat
resistant hoses (C) for cylinder four and fire resistant
hydraulic oil (D).
The breaker heat protection kit (E) includes heat-
resistant hoses, cooling extension to the breaker, and
a long working tool.
The air flow to the installed tool on the product can be
adjusted with an adjustable valve (F) on arm 1. Keep
the airflow valve open 6-turns out of 7 when the product
D
B
A
1401 - 005 - 11.01.2024

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxr 145Dxr 275Dxr 305Dxr 315

Table of Contents