13

sflow polling-interval (global version)

sflow polling-interval (global version)
Configures the polling interval globally.
Synopsis
sflow polling-interval interval value
no sflow polling-interval
Operands
interval value
Defaults
The default global counter polling interval value is 20 seconds.
Command
Global configuration mode
Modes
Description
Use this command to configure the polling interval globally. The interval is the maximum number of
seconds between successive samples of counters to be sent to the collector.
Use the no sflow polling interval interval command to return to the default value.
Usage
There are no usage guidelines for this command.
Guidelines
Examples
To set the polling interval to 135 seconds:
See Also
sflow polling interval (interface version)
220
Specifies a value in seconds to set the polling interval. The range of valid
values is 1-65535.
switch(config)#sFlow polling interval 135