Switchport Converged - Dell 8 Command Reference Manual

Dell converged enhanced ethernet command reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

switchport converged

Adds or removes native and tagged VLANs on a Layer 2 interface.
Synopsis
switchport converged {vlan vlan_id | allowed vlan {add vlan_id | all | except vlan_id | none |
remove vlan_id}}
no switchport converged
Operands
vlan vlan_id
allowed vlan
Defaults
The default native VLAN for a converged interface is 1.
Command
Interface configuration mode
Modes
Description
Use this command to add or remove tagged VLANs on a Layer 2 interface.
Usage
There are no usage guidelines for this command.
Guidelines
Examples
To set the native VLAN of 200 on an interface:
To set the tagged VLAN on an interface to 100:
To remove the tagged VLAN 100 from the interface:
See Also
show vlan brief, show interface switchport, switchport mode, switchport trunk
Dell Converged Enhanced Ethernet Command Reference
53-1002115-01
Sets the default native VLAN for the Layer 2 interface.
Sets the VLANs that will transmit and receive through the Layer 2 interface.
add vlan_id
Adds a VLAN to transmit and receive through the Layer2 interface. The range
of valid values is 2-3583.
all
Allows all VLANs to transmit and receive through the Layer 2 interface.
except vlan_id
Allows all VLANs except the VLAN ID to transmit and receive through the Layer
2 interface. The range of valid values is 2-3583.
none
Allows no VLANs to transmit and receive through the Layer 2 interface.
remove vlan_id Removes a VLAN that transmits and receives through the Layer 2 interface.
The range of valid values is 2-3583.
switch(conf-if-te-0/19)#switchport converged vlan 200
switch(conf-if-te-0/19)#switchport converged allowed vlan add 100
switch(conf-if-te-0/19)#switchport converged allowed vlan remove 100
switchport converged
3
53

Advertisement

Table of Contents
loading

Table of Contents