Whenever a security-enabled physical disk is powered on, it requires the
correct security key from the RAID controller module before it can read or
write data. So, a security-enabled physical disk uses two keys: the physical disk
key that encrypts and decrypts the data and the security key that authorizes
the encryption and decryption processes. The set storageArray securityKey
command commits the security key to all of the RAID controller modules and
security-enabled physical disks in the storage array. The self-encrypting disk
feature ensures that if a security-enabled physical disk is physically removed
from a storage array, its data cannot be read by any other device unless the
security key is known.
Set Storage Array Time
This command sets the clocks on both RAID controller modules in a storage
array by synchronizing the RAID controller module clocks with the clock of
the host from which you run this command.
Syntax
set storageArray time
Parameters
None.
261
Script Commands