Data; Station Timer Assignments - Toshiba Strata CTX Programming Manual

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

Data

Programs Used: 208, 210 and 216
Assign Timers, Paging and other related station data using the programs that follow.
1. Complete the
Record Sheets"
2. From the Program Menu click
Station > Assignment.
3. Click on the Data tab (shown
right).
4. Enter a DN number in the
Primary DN field.
...or select an existing record by
clicking one of the following
buttons:
• List – view a summary list of
programmed DKTs.
• Extended List – view a
detailed list of programmed
DKTs.
• Copy – Enter a DN in the Primary DN field and click Copy. Enter a new DN to assign existing
Station Timer settings.
5. Select the desired values. See descriptions below.
6. Click Submit.

208 Station Timer Assignments

Prerequisite Program:
Assigns timing parameters to Primary DNs.
F
IELD
Primary DN
01 ABR Retry Count
02 ABR Retry Interval
Timer
03 ABR Recall Timer
04 Hold Recall Timer
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
"Station Data
on
page
D-18.
200
on page 5-1
D
ESCRIPTION
Enter the Primary DN.
Possible values: Up to 5 digits (default = no value)
Enter the number of retry attempts made by ABR when dialing a busy telephone
number.
Possible values: 5~20 (default = 15)
Select the amount of time (in seconds) ABR waits between dialing attempts.
Possible values: 30~180 (default = 60)
Select the number of seconds ABR will call back the station after receiving ring
back tone from the dialed number.
Possible values: 5~60 (default = 20)
Select the number of seconds before a call is placed on hold recalls.
Possible values: 0~255 (default = 60)
Station
Assignment
5-21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx100Strata ctx670

Table of Contents