T1 Trunk Card - Toshiba Strata CTX Programming Manual

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

Trunks

315 T1 Trunk Card

315 T1 Trunk Card
Prerequisite Program:
This command assigns T1 Trunk Card Data to the system.
1. Complete the
Record Sheet"
2. From the Program Menu, click
Trunk > T1. The T1 Trunk Card
Data Assignment screen displays
(shown right).
3. Enter T1 card location in Shelf/Slot
field (xxyy). The selected slot
requires a DTU Card.
• xx = Cabinet 01~07
• yy = Slot 01~10
...or click the following buttons:
• List – to view a summary list of programmed Trunks.
• Copy – to T1 trunk equipment.
4. Enter values for Program 315.
5. Click Submit.
F
IELD
T1 Equipment
Location
01 Coding Format
02 Frame Format
04 Receive PAD
05 Send PAD
6-20
100
on page 4-1
"Trunk Timer/DIT
on
page
D-27.
D
ESCRIPTION
Enter the RDTU PCB equipment location.
Possible values: xx = cabinet 01; yy =slot 03, 05, or 07
Select the Coding Format.
Possible values: None, PZC, B8ZS (default) or ZCS
Select the Frame Format.
Possible values: SF Mode or ESF Mode (default)
Select the Receive PAD values.
Possible values: None, Plus 6 dB, Plus 3 dB, Zero dB (default), Minus 3 dB, Minus
Select the Send PAD values.
Possible values: None, Plus 6 dB, Plus 3 dB, Zero dB (default), Minus 3 dB, Minus
...or xx = cabinet 02~07; yy =slot 01, 03, or 05
Cabinet – Select 01 for Base and Expansion cabinet (CTX100).
Select 01 for Base and 02~07 respectively for each Expansion
cabinet (CTX670).
Slot – Select 01~04 for Base slots and 05~08 for Expansion slots
(CTX100).
Select 01~08 for Base slots and 01~10 for Expansion slots
(CTX670)
(default = no value)
6 dB, Minus 9 dB, Minus 12 dB or Minus 15 dB
6 dB, Minus 9 dB, Minus 12 dB or Minus 15 dB