Toshiba Strata CTX Programming Manual page 341

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

Programs 316~317
(continued)
Button
Sequence
316-01
Equipment Number
, xxyyzz,
A7
C‚yq
316-02
Trunk ID
, n,
A7!
C‚yq
316-03
D Channel Provided
, n,
A7"
C‚yq
316-04
Backup D Channel
Position
, n,
,
A7#
C‚yq
C‚yq
317
ISDN BRI Trunk
,
" &
C‚yq
317-00
Channel Group
n,
C‚yq
317-01
Equipment Number
, xxyyzz,
A7
C‚yq
317-02
Protocol
, n,
A7!
C‚yq
317-03
ILG
, n,
A7"
C‚yq
317-04
OLG
, n,
A7#
C‚yq
317-05
Connection Format
, n,
A7$
C‚yq
317-06
Bearer Svc - Speech
, n,
A7%
C‚yq
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
Value(s)
xx =
xx = Cabinet 01, yy = 03,
yy =
05, or 07 and zz = Channel
zz =
01 is always used to assign
RPTU parameters
or
xx = Cabinet 02~10,
yy = 01, 03, or 05 and
zz = Channel 01 is always
used to assign RPTU
parameters
n =
0~126
(default = 1)
n =
1. D-Channel
2. No D-Channel (default)
n =
1~128
(default = 24)
n =
1~32 (CTX100)
1~48 (CTX670 Basic)
1~128 (CTX670 Exp.)
xx =
CTX670
yy =
Cabinet (01~07)
zz =
Slot (01~10)
Circuit (01~08 or 01~24)
or
CTX100
Cabinet (01)
Slot (01~08)
Circuit (01~04)
n =
1. National ISDN
2. ETSI
3. TTC
4. National ISDN Nortel
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
n =
1. Point to Point
2. Point to Multi Point
n =
1. Enable (default)
2. Disable
Telephone Button Programming
Summary
Enter the ISDN RPTU equipment number as xxyyzz:
Example: If the RPTU is installed in cabinet shelf 5, slot 3, enter
050301.
Cabinet numbers:
CTX100: Select 01 for Base and Expansion cabinet.
CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
CTX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670: Select 01~08 for Base slots and 01~10 for Expansion slots..
An identifier must be used as part of the addressing to communicate
with the PSTN which channel on which link is used the given call. This
identifier is assigned by the connected PSTN.
If a backup 'D' Channel is to be used, it needs to be enabled.
Channel Group Number.
The following program enables set up for ISDN related system
settings.
Enter the BRI channel Group Number.
Enter the equipment number xxyyzz to which the ISDN BRI Trunk is
to be assigned.
Example: If the RBUU is installed in cabinet shelf 5, slot 3, enter
050301 for circuit 1.
Cabinet numbers:
CTX100 – Select 01 for Base and Expansion cabinet.
CTX670 – Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
CTX100 – Select 01~04 for Base slots and 05~08 for Expansion
slots.
CTX670 – Select 01~08 for Base slots and 01~10 for Expansion
slots.
Select the ISDN protocol. Only Bearer capabilities specified by the
protocol can be entered in this field. The Initial value for ISDN
Protocol corresponds to information set in the hardware level.
National ISDN = North America, ETSI = England and TTC = Japan.
ILG assignments must be made for basic ISDNs to process the calls
being received.
OLG assignments must be made for basic ISDNs to process the calls
being originated.
Identify connection format with the PSTN is 1- Point-to-Point or 2-
Point-to-Multipoint.
Enable speech capability.
300 Series Programs
13-63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx100Strata ctx670

Table of Contents