The following example shows you how to configures a source as a physical interface only for ERPM.
Dell(conf)#monitor session 3 type erpm
Dell(conf-mon-sess-3)#)source vlan 100 dir rx
Dell(conf-mon-sess-3)# erpm source-ip 1.1.1.1 dest-ip 100.1.1.2
Dell(conf-mon-sess-3)# flow-based enable
Dell(conf-mon-sess-3)# no disable
The following example configures the port extender ports so that they are tagged and untagged members of
VLAN 100. With regard to the source as a VLAN, the supported direction of mirroring is rx only. You must also
apply an access list to the VLAN with the rules that match with the keyword "monitor".
Dell(config-ext-macl)#do sh run mac
!
mac access-list extended test
seq 10 permit any any count monitor
Dell(config-ext-macl)#
Dell(config-ext-macl)#do sh run int vlan 100
!
interface Vlan 100
no ip address
tagged peGigE 3/0/1
mac access-group test in
shutdown
Dell(config-ext-macl)#