Dell C9000 Series Networking Configuration Manual page 841

Hide thumbs Also See for C9000 Series:
Table of Contents

Advertisement

The above procedure brings up the devices in Dell Networking OS 9.10(0.0). To get a dual homing
setup, you need to have a VLT domain running in two systems with the same OS version. Refer to
Setting up Dual
Homing.
When you upgrade a standalone system to OS 10.0(0.0) and then connect a PE later, there might be a
mismatch between the versions. In this situation, the PE remains offline and the system displays the
following:
Dell#
Apr 3 05:47:19: %RPM1-P:CP %DOWNLOAD-6-VERSION_MISMATCH_INFO: Received checkin
from PE 200. Expected version = 9-10(0-60) checkin version = 9.9(0.0)
Apr 3 05:47:20: %RPM1-P:CP %DOWNLOAD-6-UPGRADE_PROGRESS: PE 200 firmware auto
sync is in progress.
Apr 3 05:47:21: %RPM1-P:CP %BRM-5-PE_UNIT_DOWN: PE:200 Unit:2 Unit
MAC:f8:b1:56:00:02:8a is operationally down.
Apr 3 05:47:22: %RPM1-P:CP %BRM-5-BRM_LOG_PE_UNIT_VALIDATE_ERROR: PE:200 Unit:
2 is in error: SW and CAM ACL Validation error state.
Dell#show pe brief
--
Port Extenders Information
----------------------------------------------------------
PE-id
Status
----------------------------------------------------------
200
offline
Dell#show pe 200
Codes:
A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 200
Status: offline
System Mac: f8:b1:56:00:02:8a
PE Up Time: 00:00:00
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/22(A),Te 0/23(A)
Cascade LAG: Po 458(Up)
------------------------------------------------------------------------
Stack-id
Status
------------------------------------------------------------------------
2
error
Dell#
Dell#show pe errors
PE-id: 200
PE MAC: f8:b1:56:00:02:8a
PE Unit Errors:
PE Unit:2, Error Reason: SW Mismatch
Dell#
The PE goes for an auto-synch to get upgraded to the version that matches the CB. Once synched, the
PE comes up online.
Dell#Apr 3 05:52:49: %RPM1-P:CP %DOWNLOAD-6-UPGRADE: PE 200 auto upgrade
result - upgrade success, initiating reset.
Apr 3 05:52:52: %RPM1-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to
down: Te 0/22
Apr 3 05:52:52: %RPM1-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to
down: Te 0/23
Stack-size
Type
1
C1048P
Reason
Type
SVM
C1048P
--
System-MAC
f8:b1:56:00:02:8a
UnitMac
00:00:00:00:00:00
No. of Ports
52
Port Extenders (PEs)
841

Advertisement

Table of Contents
loading