High Availability In A Pe Stack; Online Insertion And Removal; Rpm Online Insertion; Line Card Online Insertion - Dell C9000 Series Networking Configuration Manual

Hide thumbs Also See for C9000 Series:
Table of Contents

Advertisement

High Availability in a PE Stack

A port extender (PE) stack has a master and standby management unit that provide redundancy in a similar
way to redundant route processor modules (RPMs).
If the master stack unit fails or is removed, the standby unit becomes the stack manager. The stack elects a
new standby unit and resets the failed master unit. The failed master becomes online as a member unit; the
remaining members remain online.
For more information about the failover process in a PE stack, see the

Online Insertion and Removal

You can add, replace, or remove chassis components (RPMs, line cards, fan modules, power supplies) while
the switch is operating. C9010 RPMs and line cards are hot-swappable. Use the information in this section
when inserting an RPM or line card in the C9010 chassis. For more information about how to install an RPM
or line card in the C9010, see the C9010 Getting Started Guide or C9010 Installation Guide.

RPM Online Insertion

Dell Networking systems can function with only one RPM. If you insert a second RPM, it comes online as the
standby RPM. To display the status of installed RPMs, enter the show rpm all command.
Dell# show rpm all
--
Route Processor Modules --
Slot
Status
------------------------------------------
0
active
1
standby

Line Card Online Insertion

When you insert a line card into an online chassis, the Dell Networking OS detects the line card type. The
system writes the line card type to the running configuration and maintains this information as a logical
configuration if you remove the card. To display the status of installed line cards, enter the show linecard
all command.
Dell# show linecard all
--
Linecard Info
LinecardId
Type
----------------------------------------------------------------------------
0
Linecard
1
Linecard
2
Linecard
NxtBoot
Version
online
1-0(0-4095)
online
1-0(0-4095)
--
Status
ReqTyp
online
C9000LC2410T
online
C9000LC2410G
online
C9000LC2410T
Port Extender (PE) Stacking
CurTyp
Version
C9000LC2410T
1-0(0-4095)
C9000LC2410G
1-0(0-4095)
C9000LC2410T
1-0(0-4095)
High Availability (HA)
chapter.
Ports
24
24
24
469