Communication
10.1 Communication according to PROFIdrive
Bit
Meaning
5
Reserved
6
Reserved
7
Alarm active
No alarm active
8
SYNC
9
Alarm is active
10
Fault pending
11
Safety Integrated module line-up
group message
12
Slave sign-of-life bit 0
13
Slave sign-of-life bit 1
14
Slave sign-of-life bit 2
15
Slave sign-of-life bit 3
E_DIGITAL (digital inputs)
See function diagram [2498].
Table 10- 45 Description of E_DIGITAL (digital inputs)
Bit
Meaning
0
Digital input/output 8
(DI/DO = 8)
1
Digital input/output 9
(DI/DO = 9)
2
Digital input/output 10
(DI/DO = 10)
3
Digital input/output 11
(DI/DO = 11)
4
Digital input/output 12
(DI/DO = 12)
566
-
-
-
-
1
The active alarms are stored in the alarm buffer
0
There are no alarms in the alarm buffer
SYNC bit of TM17 indicates that the slave is synchronized.
1
Slave synchronized
0
Slave not synchronized
1
There is no alarm in the module line-up.
0
Alarm in the module group is active, OR'ed across
all DOs including the Control Unit of the module
line-up.
1
No group bit for fault in the module line-up.
0
Group bit for module line-up fault is active, OR'ed
across all DOs including the Control Unit for the
module line-up, incl. propagation.
1
No group bit for SI fault
0
Group bit for SI fault is active, OR'ed across all of
the drive objects, including the Control Unit of the
module line-up, including propagations.
1-15 Cyclic advance
0
Initialization, no sign of life available
1-15 Cyclic advance
0
Initialization, no sign of life available
1-15 Cyclic advance
0
Initialization, no sign of life available
1-15 Cyclic advance
0
Initialization, no sign of life available
DI/DO 8 on the Control Unit must be parameterized as an input
(p0728.8 = 0).
DI/DO 9 on the Control Unit must be parameterized as an input
(p0728.9 = 0).
DI/DO 10 on the Control Unit must be parameterized as an input
(p0728.10 = 0).
DI/DO 11 on the Control Unit must be parameterized as an input
(p0728.11 = 0).
DI/DO 12 on the Control Unit must be parameterized as an input
(p0728.12 = 0).
Remarks
Remarks
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Parameter
-
-
BO: 2139.7
BO: r0899.8
BO: r3114.9
BO: r3114.10
BO: r3114.11
Implicitly
interconnected
Parameter
BO: p0722.8
BO: p0722.9
BO: p0722.10
BO: p0722.11
BO: p0722.12
Drive functions