Siemens Sinamics S120 Function Manual page 64

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Extended setpoint channel
2.8 Suppression bandwidths and setpoint limits
Function diagrams (see SINAMICS S120/S150 List Manual)
● 1550 Setpoint channel
● 3050 Suppression bandwidth and speed limiting
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Setpoint limitation
● p1080[D] Minimum speed
● p1082[D] Maximum speed
● p1083[D] CO: Speed limit in positive direction of rotation
● r1084 CO: Speed limit positive effective
● p1085[C] CI: Speed limit in positive direction of rotation
● p1086[D] CO: Speed limit negative direction of rotation
● r1087 CO: Speed limit negative effective
● p1088[C] CI: Speed limit negative direction of rotation
● p1106[0...n] CI: Minimum speed
● r1119 CO: Ramp-function generator setpoint at the input
Skip frequency bands
● p1091[D] Suppression speed 1
● ...
● p1094[D] Suppression speed 4
● p1101[D] Suppression speed bandwidth
Parameterization with STARTER
The "speed limitation" parameter screen is selected by activating the following icon in toolbar
of the STARTER commissioning tool:
Figure 2-11
62
STARTER icon for "speed limitation"
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents