● p1590[0...n] Flux controller P gain
● p1592[0...n] Flux controller integral time
Commissioning with STARTER
The "current controller" parameterizing screen is selected via the following icon in the toolbar
of the STARTER commissioning tool:
Figure 3-13
3.7

Current setpoint filters

Description
The four current setpoint filters connected in series can be parameterized as follows:
● Low-pass 2nd order (PT2: -40 dB/decade) (type 1)
● General filter 2nd order (type 2)
The phase frequency curve is shown alongside the amplitude log frequency curve. A phase
shift results in a control system delay and should be kept to a minimum.
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
STARTER icon for "current controller"
Bandstop and lowpass with reduction are converted to the parameters of the general filter
2nd order using the STARTER commissioning tool.
– Bandstop
– Low-pass with reduction by a constant value
Servo control
3.7 Current setpoint filters
85