12.14 Write and know-how protection
Parameters without write protection
Certain parameters are excluded from write protection in order not to endanger the
functionality and operability of the drives. The list of these parameters can be found in the
SINAMICS S120/150 List Manual in the Chapter, Parameters for write protection and know-
how protection, subchapter, Parameters with "WRITE_NO_LOCK".
The function "restore factory settings" is also not locked when write protection is activated.
12.14.2

Know-how protection

The know-how protection function (KHP) prevents e.g. strictly confidential company know-
how for configuration and parameter assignment from being read.
The know-how protection requires a password. The password must comprise at least 1 and
a maximum of 30 characters.
Note
Password security
You are responsible for the security of your password. We recommend that you use a
password with adequate length, which includes upper and lowercase letters and special
characters.
If you set the password via a network connection, then it is possible that unauthorized
persons can "listen in" without being noticed. Therefore, we recommend that you establish a
direct connection to the Control Unit to set the password.
Characteristics when know-how protection is activated:
● Certain parameters are locked. In the expert list, the value of these parameters cannot be
● In the locked parameters of the expert list of STARTER, the text "know-how protected" is
● The locked parameters of the expert list can be hidden using a filter.
● The values of display parameters remain visible.
● The contents of screen forms are not displayed when know-how protection is active.
● Know-how protection can be combined with copy protection.
Functions locked using know-how protection
The following listed functions are inhibited when know-how protection is active:
● Download
● Export/import
780
read or changed.
present in black lettering on a pink background instead of the parameter values.
– To do this, click on the drop-down list "Online value of the Control Unit" on the triangle.
– If you select the entry "Without know-how protection", the know-how-protected
parameters will be hidden.