● Current and torque limitation
● Current controller adaptation
● Flux control
Closed-loop current control
No settings are required for operating the current controller. Optimization measures can be
taken in certain circumstances.
Current and torque limitation
The current and torque limitations are initialized when the system is commissioned for the
first time and should be adjusted according to the application.
Current controller adaptation
The P gain of the current controller can be reduced (depending on the current) by means of
current controller adaptation. Current controller adaptation can be deactivated with the
setting p1402.2 = 0.
Figure 3-12
Flux controller (for induction motor)
The parameters for the flux controller are initialized when the system is commissioned for the
first time and do not usually need to be adjusted.
Function diagrams (see SINAMICS S120/S150 List Manual)
● 5710 Current setpoint filters
● 5714 Iq and Id controller
● 5722 Specified field current, flux reduction, flux controller
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Current controller adaptation
Servo control
3.6 Current controller