Vector control

4.18 Instructions for commissioning permanent-magnet synchronous motors

4.18
Instructions for commissioning permanent-magnet synchronous
motors
Equivalent circuit diagram for synchronous motor and cable
Figure 4-25
Permanent-magnet synchronous motors, rotating
Permanent-magnet synchronous motors with or without encoder are supported.
The following encoder types are supported:
● Encoder with position information (e.g. without CD track or reference signal)
● Encoder without position information
For operation without encoders or with encoders without position information, a pole position
identification must be carried out (see the chapter on pole position identification for further
details).
Typical applications include direct drives with torque motors, which are characterized by high
torque at low speeds. When these drives are used, gear units and mechanical parts subject
to wear can be dispensed with if the application allows this.
Temperature protection can be implemented using a temperature sensor (KTY/PTC). In
order to achieve a high torque accuracy, we recommend that a KTY temperature sensor is
used.
Table 4- 6
Parameter
p0304
p0305
p0307
188
Equivalent circuit diagram for synchronous motor and cable
Motor data
Description
Rated motor voltage
Rated motor current
Rated motor power
Remark
If this value is not known, a "0" can also be
entered. Using this value, the stator leakage
inductance can be more precisely calculated
(p0356, p0357).
-
-
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2