Bosch SE3000 Series Technical Reference Manual page 117

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

Security Escort
Element
Supervision
Supervision period
Lanyard
Name
Address
City
State
Zip
Phone
Subscriber ID
Transmitter ID / New ID
Alarm Zone
Robert Bosch (SEA) Pte Ltd
Troubleshooting coordinators, points and receivers | en 117
Usage/Description
If this checkbox is not selected, the supervision feature will not
be enabled during an alarm. If this checkbox is selected, the
supervision feature will be enabled during an alarm. This option
also affects the availability of the Supervision period field.
If the Supervision checkbox is selected, this field is enabled for
user to change the period of the supervision feature in seconds
during an alarm. Default is 90, and valid values are numeric
between 5 and 86400.
If this checkbox is selected, the lanyard feature will not be
enabled. If this checkbox is selected, the lanyard feature will be
enabled.
The individual or item assigned to this transmitter. This is a
compulsory field.
Address of the individual or item within the protected area. The
first address line on the left side, which is not the home address,
is shown on the alarm screen
City of the individual or item within the protected area.
State of the individual or item within the protected area.
Zip code of the individual or item within the protected area.
The phone number to access the individual within the protected
area. The phone number on the left side, which is not the home
phone, is shown on the alarm screen.
The Subscriber ID (typically the Social Security Number) must be
entered into this field. This is a compulsory field. It must be filled
in with a unique ID.
The transmitter identification code can be typed into this field,
but a faster and error free method is to delete any existing entry
in the Transmitter ID field and then perform a test with the
transmitter to be assigned to this subscriber. The new
transmitter ID will be populated in the New ID field. The new ID
must then be manually entered into the Transmitter ID field, or
use the mouse to highlight the existing Transmitter ID and press
and hold the <Shift> key and press the <Insert> key. This
transfers the new ID to the Transmitter ID field. This is a
compulsory field that must be filled with a unique ID. Complete
the change to the Subscriber record by clicking the [Save]
button.
Specific alarm zones are assigned to the different computer
workstations of the Security Escort system. Each transmitter
entered in the Subscriber database can be assigned to one or
more of the alarm zones. You may control on which computer
workstations alarms from this transmitter appear.
Technical Reference Manual