Bosch SE3000 Series Technical Reference Manual page 39

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

Security Escort
The SE receivers use addresses 1 to 15. Configure the four switches from the left, 1, 2, 3 and
4 of dip switch ADDR as the address of the device.
Address
0
(used for coordinator only)
1
(default setting for receiver)
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Tab. 5.3: Address settings on dip switch ADDR
Setting the jumpers for RS-485
For RS-485 communication, it is necessary to include the end of line jumper settings on the
last SE receiver to have a stable communication channel. Set the jumper for the SE
coordinator and the SE receivers as of below:
1.
Robert Bosch (SEA) Pte Ltd
For the SE coordinator and the last SE receiver only, locate the jumper block J5 and set
the jumper over the jumper pins 1 and 2. This is the default factory setting on the SE
coordinators/SE receivers.
Technical Reference Manual
Switch Number on Dip Switch ADDR
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
System wiring | en
39
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
2018.03 | SE3v1.0 | DOC