Bosch SE3000 Series Technical Reference Manual page 24

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

24
en | Equipment estimation
Figure 4.3: SE receiver Spacing
1.
2.
3.
4.
Using an SE coordinator, SE receivers and laptop computer to determine SE receiver
location.
Notice!
System software and area map must be installed on laptop computer to use this method.
Before the SE receivers are mounted, an SE coordinator with long RS-485 wires connected to
the SE receivers can be used to see actual alarm location. Place the SE receivers in the
proposed locations wired back to the SE coordinator. Program the SE receivers with their
locations in the Transponder Database.
Using the maintenance SE transmitter and the maintenance alarm database, activate alarm
transmissions within the area surrounded by the temporarily placed SE receivers. Verify that
the location accuracy is acceptable at all points of concern. If not acceptable, move the SE
receivers, update the SE receiver location in the Transponder Database and retest.
Do not test outside of the last SE receiver in any direction, as this will give incorrect locations.
Repeat this test in all areas of different construction and concerns at the site.
2018.03 | SE3v1.0 | DOC
1 SE receiver 1 stops sounding the test
beeps when SE receiver 2 is moved
past this point
2 SE receiver 1
Mount the first SE receiver (SE receiver 1). Set switch number 1 of dip switch CFG2 to
the ON position. Power the SE receiver from a 12 VDC source.
Take the second SE receiver (SE receiver 2) and an SE transmitter a distance away from
the first SE receiver (SE receiver 1).
Activate the SE transmitter.
If SE receiver 1 sounds the test beep, SE receiver 2 is within range. Repeat this test until
SE receiver 1 no longer sounds the test beeps. Move back to the last location where SE
receiver 1 received the test beeps. This location marks the maximum spacing between
the SE receivers. The distance between the SE receivers should not exceed 25 m (80 ft)
indoors and 90 m (300 ft) outdoors. Mount SE receiver 2 at this location or closer to SE
receiver 1.
Technical Reference Manual
3 SE receiver 2 at maximum range
4 SE receiver 2 beyond maximum range
Robert Bosch (SEA) Pte Ltd