Bosch SE3000 Series Technical Reference Manual page 195

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

Security Escort
Element
[Not Responding Map]
[Out of Service Map]
[Reset Transponder
Troubles]
[Jamming Map]
[Tamper Map]
[Input 1 Map]
[Input 2 Map]
[Previous]
[Next]
[Acknowledge]
[Refresh Data]
[Cancel]
10.4.6
Transponder parameter change
This dialog allows parameters stored in the SE coordinator's EEPROM memory to be viewed
and changed.
Robert Bosch (SEA) Pte Ltd
Usage/Description
To assist in diagnosing problems with the SE receivers associated
with an SE coordinator, several commands can be issued from the
Central Console to requesting information from the SE
coordinator. This button requests a map of all the devices on this
SE coordinator that are not responding to the system. The current
troubles list is automatically updated.
This button requests a map of all devices on this SE coordinator
that were manually taken out of service to the system. The current
troubles list is automatically updated.
This button is used to reset all of the alarm, test and message
counters to zero, and to remove any restoration reports.
This button requests a map of all the SE receivers on this SE
coordinator that are reporting a jamming condition to the system.
The Current Troubles list is automatically updated.
This button requests a map of all the devices on this SE
coordinator that are reporting a tamper condition to the system.
The current troubles list is automatically updated.
This button requests a map of all Input 1s on this SE coordinator
that are reporting an activation to the system. The current troubles
list is automatically updated.
This button requests a map of all the Input 2s on this SE
coordinator that are reporting an activation to the system. The
current troubles list is automatically updated.
Returns to the previous SE coordinator.
Advances to the next SE coordinator.
Clicking this button removes all restored troubles from the current
troubles list.
Clicking this button updates all of the SE coordinator level data in
this screen. It does not update the device troubles (use stress test
or auto scan to update the device troubles).
Clicking this button cancels all commands and closes the dialog
window.
Technical Reference Manual
System menus and dialogs | en 195
2018.03 | SE3v1.0 | DOC

Advertisement

Table of Contents
loading

Table of Contents