Bosch SE3000 Series Technical Reference Manual page 40

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

40
en | System wiring
2.
Testing SE receiver spacing
The spacing mode can be used to verify the maximum acceptable spacing of SE receivers.
Enable or disable the spacing mode by setting switch number 1 on dip switch CFG2. Spacing
mode is disabled by default, where switch number 1 is set to the OFF position. To enable the
spacing mode, set switch number 1 on dip switch CFG2 to the ON position.
Enable/disable Spacing Mode
Disable Spacing Mode
(default setting)
Enable Spacing Mode
Tab. 5.4: Enable or disable the spacing mode on dip switch CFG2
To test the spacing of SE receivers:
1.
2.
3.
4.
2018.03 | SE3v1.0 | DOC
For all SE receivers except the last SE receiver, locate the jumper block J5 and set the
jumper over the jumper pins 2 and 3.
Mount the first SE receiver (SE receiver 1). Set switch number 1 on dip switch CFG2 to
the ON position. Power the SE receiver from a 24 VDC source.
Take the second SE receiver (SE receiver 2) and an SE transmitter a distance away from
the first SE receiver.
Activate the SE transmitter.
If SE receiver 1 sounds the test beep, SE receiver 2 is within range. Repeat this test until
SE receiver 1 no longer sounds the test beeps. Move back to the last location where SE
receiver 1 received the test beeps. This location marks the maximum spacing between
the SE receivers. The distance between the SE receivers should not exceed 25 m (80 ft.)
indoors and 90 m (300 ft.) outdoors. Mount SE receiver 2 at this location or closer to SE
receiver 1.
Technical Reference Manual
Switch Number on Dip Switch CFG2
1
OFF
ON
Security Escort
Robert Bosch (SEA) Pte Ltd

Advertisement

Table of Contents
loading