Operations For The Se Receiver; Scanning Se Receivers - Bosch SE3000 Series Technical Reference Manual

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

Security Escort
Notice!
Note that the Status column of the SE Coordinators grid view may show as FAIL for the
successful firmware upload. The latest status is not automatically refreshed in the list after
the upload. Click the [Scan Coordinators] button to refresh the list and status.
9.
8.2

Operations for the SE receiver

8.2.1

Scanning SE receivers

Follow the instructions below to list the SE receivers that are connected to the SE
coordinator. Connected Receivers are SE receivers already connected (added) to an SE
coordinator. Available Receivers are SE receivers on the same bus that are available to be
added to the SE coordinator. You may scan the SE receivers for only one SE coordinator at any
one time.
1.
2.
3.
Robert Bosch (SEA) Pte Ltd
For each unsuccessful firmware upload, an error message window appears.
Click the [Scan] button under the Receivers column for the row entry of the SE
coordinator from the SE Coordinators grid view.
The Utility tool scans for the SE receivers. An indicator bar appears on screen to display
the scanning progress.
Upon completion of the scan, the indicator bar shows the completed status.
SE receivers that are connected to the SE coordinator, appear in the Connected
Receivers grid view.
SE receivers that are available appear in the Available Receivers grid view.