Bosch SE3000 Series Technical Reference Manual page 185

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

Security Escort
Figure 10.19: Popup trouble filter dialog
Element
Transponder troubles group
AC loss
Low battery
Tamper (no delay)
Remote key activation
Robert Bosch (SEA) Pte Ltd
Usage/Description
The SE coordinator senses when it loses AC power and reports the
condition to the Central Console. After a few seconds delay, the
Central Console generates the notification and records the
condition in the audit file. See Transponder current status dialog.
Periodically during normal operation, the SE coordinator tests its
battery. If the test fails, it immediately reports the condition to the
Central Console. After a few seconds delay, the Central Console
generates the notification and the condition is recorded in the
audit file.
The SE coordinator immediately senses and reports the actuation
of its tamper switch. The Central Console immediately generates
the notification and records the condition in the audit file without
delay.
The SE coordinator immediately senses and reports the activation
(shorting) of its remote key input when it is enabled in the
Transponder parameter change dialog. The Central Console
generates the notification and records the condition in the audit
file.
Technical Reference Manual