External Offset Values: Ofs - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-10-3 External offset values: OFS

Sets offset value of marking position used for "External Offset Function" with I/O input.
⿎ Setting request data / response data for readout
Start
OFS
code
command
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
OFS
code
⿎ Data description
Data length
Name
[byte]
Data number
X-movement
Y-movement
Rotation
movement
Total data length
• This command can be used when the input method of the external offset is I/O input setting. If "Using SEO command" is
set, switch the command mode to the standard mode by RSM command and then send SEO command.
• With LP-400/V compatible command mode, Z-movement and laser power correction of the external offset cannot be set.
For these settings, the data set last (the initial value if it was not set) will be applied.
⿎ Example of command settings
Condition:
Data number = 5, X-movement = 10, Y-movement = -5.5, Rotation movement = 90
• Setting
Transmission data
• Readout
Transmission data
Response data
[Data number] [X-movement] [Y-movement]
Sub
[Rotation movement]
[Data number]
R
3-byte
Data contents
3
"000"–"255"
8
"-999.999"–"+999.999" [mm]
8
7
"-180.00"–"+180.00" [°]
26
Fixed length.
[STX]
OFS
[STX]
OFS
[STX]
OFS
ME-LP-GS-SR-COMP-3
26-byte
(Check sum)
End code
Specifies the data number for which
the external offset is set.
• Moves the coordinate of the all
• The rotation center is the center
S
005+010.000-005.500+090.00
R
005
[CR]
A
005+010.000-005.500+090.00
(Check
End code
sum)
Remarks
marking data in the file.
of the marking field.
[CR]
[CR]
115

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents