Panasonic LP-GS Series Serial Communication Command Manual page 64

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

⿎ Automatic response data with response permitted
The following response data transmit normal end or abnormal end at the end of the trigger processing (marking) with the
marking end verification response permitted.
Start
MST
code
⿎ Data description
Name
Status
Total data length
• Refer to "Error Indication" (P.150) for error codes details.
• The automatic response data of the error code will not be transmitted in case of errors occurred when the marking
trigger processing is not in progress.
• When on-the-fly marking with multiple triggers or at regular intervals are set, the response data is transmitted at the
timing of each marking completion.
• When the marking interval is too short for transmission time of MST command, MST command is not available. In such
case, check the marking completion by I/O.
⿎ Example of command settings
Condition:
• Setting
• Readout
Condition:
• Response data with
response permitted
Condition:
• Response data with
response permitted
64
[Status]
A
4-byte
Data length
Data contents
[byte]
"0000": Normal end
4
"E001"–"E999": Error
code (abnormal end)
4
The data length is fixed.
Response setting = 1
Transmission data
Transmission data
Response data
Status = 0000 (normal end)
Response data
When the alarm E400 occurred at the marking.
Status = E400
Response data
ME-LP-GS-SR-COMP-3
(Check sum)
End code
• It returns the error code occurred in case of an
abnormal end by an error during marking trigger
processing.
• When the warning that does not interrupt the
marking operation (E700 to E799) occurs, the
response data indicates "0000" as the normal end.
[STX]
MST
S
1
[STX]
MST
R
[CR]
[STX]
MST
A
1
[STX]
MST
A
0000
[STX]
MST
A
E400
Remarks
[CR]
[CR]
[CR]
[CR]