nSwitchToTaskAfterTermination = -2
fFindWindowWithWildcards
With this parameter, a wildcard search can be activated for the attribute Windowname. In this
way it is possible to identify applications that do not have the same attribute window name at
every start, e.g. access level, time-of-day under window name, etc.:
fFindWindowWithWildcards
= 0
= 1
Example
An application is to be integrated that contains the start time in the attribute window name:
oemframe.ini
[MyQtTest]
fFindWindowWithWildcards = 1
systemconfiguration.ini
[processes]
PROC500=process:=ProcessOEM, cmdline:="C:\\Program Files(x86)\\Siemens\\
MotionControl\\oem\\sinumerik\\hmi\\appl\\MyQtTest.exe",oemframe:=true,
windowname:="MyQtTest - ??:??:??", classname:="QWidget",deferred:=true
[areas]
AREA500=name:=Test, process:=ProcessOEM
23.3
FindWindow program application
Via the FindWindow program, you can determine all the parameters in the
"systemconfiguration.ini" file that are relevant for integrating an OEMFrame application into
SINUMERIK Operate.
Requirement
To use the FindWindow program, you require access level 2 (service).
Installation
FindWindow can be used on any PCU without being installed.
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Wildcard search is switched off
Wildcard search is switched on
Wildcard:
One arbitrary character
?
Any number of characters
*
SINUMERIK Operate on PC/PCU
23.3 FindWindow program application