Registering the alarm text file
You still have to register your alarm text file so that the system knows your alarm texts during
the program runtime:
1. You can copy a sample configuration file "oem_slaesvcadapconf.xml" from the following
directory: /siemens/sinumerik/hmi/template/cfg
2. Save or create the file in the /oem/sinumerik/hmi/cfg or
/user/sinumerik/hmi/cfg directory.
3. Assign the name "slaesvcadapconf.xml" to the file.
4. Open the file and in the <BaseNames> tag enter the file name of your alarm text file without
language code and file extension, e.g. "my_nck_alarms", as "value". The registration of
your alarm text file starts, for example, with the name "Siemens_BaseName_01".
Note
The names of the <BaseNames> tag can be freely selected. They must be unique in the
system and must not clash with names used by Siemens.
The "Siemens_BaseName_01" name is reserved for Siemens.
Several alarm text files can also be registered. To do this, use names such as
"OEM_BaseName_02", "OEM_BaseName_03", etc.
Example:
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<!-- Configuration of the Solutionline Alarm & Event Service Adapter
-->
<CONFIGURATION>
<AlarmTexts>
</BaseNames>
</AlarmTexts>
</CONFIGURATION>
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
<name>myNckAlarms</name>
<message>
<source>10000/NCK</source>
<translation> OEM alarm text example for NCK alarm 10.000</
translation>
</message>
<BaseNames>
<OEM_BaseName_01 type="QString" value="my_nck_alarms"/>
13.2 Configuring alarm and message texts via alarm text files