Siemens SINUMERIK 840DE sl Commissioning Manual page 399

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

17.6.2.3
HMI on the PCU cannot establish a network connection to the NC
Error
HMI displays alarm 120202
"Wait for connection to NC/
PLC" and/or no values (only
'#').
Error
HMI displays alarm 120202
"Wait for connection to NC/
PLC" and/or no values (only
'#').
Error
HMI displays alarm 120202
"Wait for connection to NC/
PLC" and/or no values (only
'#').
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Error cause 1
The IP address of the target NCK/PLC
set on the PCU is incorrect.
Error cause 2.1
The PCU has an IP address that does not
belong to the network or has an invalid IP ad‐
dress.
The TCU support is deactivated on the PCU
(= DHCP is disabled) and the PCU either op‐
erates with a permanently set IP address that
does not belong to the network, or with the
standard Windows DHCP client to dynami‐
cally retrieve addresses. This is a configura‐
tion error.
Error cause 2.2
The PCU has an IP address that does not
belong to the network or has an invalid IP ad‐
dress.
The TCU support is activated on the PCU (=
DHCP is enabled) and the PCU is active
DHCP-/DNS server (either as a result of the
DHCP SyncMode ON_MASTER or as a re‐
sult of the Sync priority - just the same as the
other server candidates and random selec‐
tion) - or the PCU is a DHCP client. As a result
of a software error or the actual network con‐
figuration, the PCU cannot obtain a valid IP
address (e.g. '0 address').
Configuring the network
17.6 Station-related network diagnostics
Remedy
From the HMI, correct the target address for
NCK/PLC and restart the PCU.
Remedy
Correctly set the network settings for the sys‐
tem network in the Windows service mode
(set the fixed specified IP address and subnet
mask for the system network, use the address‐
ing mode, fixed IP address).
Execute the following actions using the "Sys‐
tem Network Center" program:
● Connect the DHCP service to the interface
for the system network
● Set the DHCP mode (TCU support, DHCP
SyncMode, address range of the
addresses that can be assigned)
● Initiate DHCP clear
Remedy
Correctly set the network settings for the sys‐
tem network in the Windows service mode
(set the fixed specified IP address and subnet
mask for the system network, use the address‐
ing mode, fixed IP address).
Execute the following actions using the "Sys‐
tem Network Center" program:
● Connect the DHCP service to the interface
for the system network
● Set the DHCP mode (TCU support, DHCP
SyncMode, address range of the
addresses that can be assigned)
● Initiate DHCP clear
In addition, at the station with DHCP master
(DHCP SyncMode = ON_MASTER) a DHCP
clear should be initiated.
385

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents