Collision avoidance
14.7 Creating a kinematic structure
Parameter
Use
Radius
Offset (X)
Offset (Y)
Offset (Z)
Rotary axis (X)
Rotary axis (Y)
Rotary axis (Z)
Angle of rotation
See also
Creating protection area elements (Page 306)
File and parallel 3D file protection area element (Page 316)
14.7.3.5
Cylinder and parallel cylinder protection area element
You can specify the dimensions and position as well as values for the display and collision
monitoring of a cylindrical protection area element in the "Cylinder" window.
312
Meaning
● Display
The protection area element is shown in the graphic view.
The element is only visible if the "Display model" softkey is active.
The element is not monitored for collision.
● Monitoring
The protection area element is used for the collision avoidance.
The element is only visible if the "Monit. model" softkey is active.
● Display + monitoring
The protection area element is used for display in the graphic view
and for collision avoidance.
The element is visible in both display versions.
Specification of the radius
X component of the direction vector.
Y component of the direction vector.
Z component of the direction vector.
X component of the rotation vector.
Y component of the rotation vector.
Z component of the rotation vector.
The value by which the system rotates around the rotation vector.