Siemens SINUMERIK 840DE sl Commissioning Manual page 165

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

10.3.2
Temperatures
Which temperatures are evaluated and displayed depends on the number and the mounting
location (e.g. for sensor S6, bearing temperature front) of the sensors installed in the spindle.
The motor temperature is not displayed when the temperature sensor sensor type parameter
p0601 = 0 or 1.
Note
Temperature limits
The limit values displayed here refer to the spindle monitoring and have no effect on the drive
parameter values set in the drive that apply for the shutdown response of the spindle. The
temperature limit values are preset in the SMI24 and cannot be changed in this window. If
necessary, you must adapt the shutdown limit values for the drive.
Up to three temperatures can be evaluated:
Signal
Motor temperature
(Page 153)
Motor temperature
Alarm
Motor temperature
Fault
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Sensor
Column/meaning
KTY
Actual
Limit
Duration of the upper
limit violation
Last upper limit viola‐
tion
Number of
upper limit violations
Limit
Duration of the upper
limit violation
Last upper limit viola‐
tion
Number of
upper limit violations
Spindle functions
10.3 Spindle diagnostics
Description
Current motor temperature. If an
overtemperature protection is
present and responds, the value 250°
C is displayed.
Stored threshold for motor overtem‐
perature as of which an alarm is is‐
sued due to KTY motor overtemper‐
ature.
Displays the accumulated hours dur‐
ing which an upper limit violation was
present.
Displays the time stamp [date] and
[time] at which the last upper limit vi‐
olation was present.
Accumulated number of upper limit
violations.
Stored threshold for motor overtem‐
perature as of which a fault is issued
due to KTY motor overtemperature.
Displays the accumulated hours dur‐
ing which an upper limit violation was
present.
Displays the time stamp [date] and
[time] at which the last upper limit vi‐
olation was present.
Accumulated number of upper limit
violations.
151