Entries
UpperLimit
LowerLimit
Example
In the following example, the <GeoRadius> parameter is used.
Only enter the modified data.
<PARAMETERCONFIGURATION>
</PARAMETERCONFIGURATION>
Configuring new list parameters based on an existing list parameter.
Assign a new parameter name and enter only the changed data:
Entries
Base
Example 1
<PARAMETERCONFIGURATION>
</PARAMETERCONFIGURATION>
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Meaning
Upper input limit for these parameters in the user interface.
Only applies for numerically entered parameters.
Lower input limit for these parameters in the user interface.
Only applies for numerically entered parameters.
<GeoRadius>
<Width value="53" type="int" />
<DisplayMode value="DoubleMode" type="QString" />
<DecimalPlaces value="2" type="int" />
</GeoRadius>
Meaning
Assign new parameter name
See example 1: Text "NewGeoRadius"
Name of the parameter on which the new parameter is based.
See example 1: "GeoRadius" parameter is used as a template.
Also enter only the changed data here. All other data is taken from the existing
parameter.
See example 1: Column width changed to 46 pixels. Number of decimal places
changed to 1.
<NewGeoRadius>
<Base value="GeoRadius" type="QString" />
<Width value="46" type="int" />
<DisplayMode value="DoubleMode" type="QString" />
<DecimalPlaces value="1" type="int" />
</NewGeoRadius>
Tool management
12.2 Configuring the user interface
193