Siemens SINUMERIK 840DE sl Commissioning Manual page 379

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Availability of the V24 serial interface
If you want to change the availability of the V24 interface, you can adjust the following
parameters in file "slpmconfig.ini":
Parameters
[V24]
useV24
Storage of file "slpmconfig.ini"
The template of the file "slpmconfig.ini" for SINUMERIK Operate is stored in the following
directory:
<Installation path>/siemens/sinumerik/hmi/template/cfg
Copy the file to one of the following directories:
<Installation path>/user/sinumerik/hmi/cfg
<Installation path>/oem/sinumerik/hmi/cfg
Note
If you want to achieve a better overview of the changes you have made yourself, simply delete
the unchanged parameters from the file copy "slpmconfig.ini".
Reading-out archives
The files to be sent (directories, individual files) are zipped in an archive (*.arc). If you send
an archive (*.arc), this is sent directly without being additionally zipped. If you have selected
an archive (*.arc) together with an additional file (e.g. directory), then these are zipped into a
new archive and are then sent.
Reading-in archives
Use interface V24 if you want to read in archives. They are transferred and then subsequently
unzipped.
Note
Reading in commissioning archives
When you read in a commissioning archive via the V24 interface, then this is immediately
activated.
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
16.8 Serial interface (V24 / RS232)
Description
Describes the section in which the relevant setting parameters
are located.
Setting for the availability of the V24 serial interface
Interface and softkeys are available (de‐
= true
fault)
Interface and softkeys are not available
= false
Data backup
365