Tool management
12.2 Configuring the user interface
12.2.1
General settings
<SETTINGS> tag
The general settings for the tool management user interface are stored in the <SETTINGS>
tag.
Entries
ReactivateWithMagPos
ReactivateAllMonitorModes
ReactivateEnabled
CreateNewToolDialog
CreateNewMultiToolDialog
MagazineSelectionDialog
172
Meaning
True - reactivate with positioning of the tool to the tool mag‐
azine loading point.
False - default setting, reactivate without positioning the tool
magazine.
True - the actual values of all the monitoring types set in the
NC are reset.
False - default setting, actual value of the active monitoring
type is reset.
True - default setting, reactivation is enabled.
False - reactivation is disabled.
True - the "New Tool" window is displayed. In this window,
you can specify the tool name and the size of the tool (over‐
sized tool) before actually creating the tool. Other input op‐
tions can be defined by configuring the "New tool" window.
False - default setting, the "New Tool" window is not dis‐
played. Once the name has been entered, the tool will be
created directly in the tool list.
True - default setting, the "New Multitool" window is dis‐
played. In this window, you can configure the following be‐
fore actually creating the multitool:
● Multitool names
● Number of multitool locations
● Type of clearance input
● Value of the location clearance for each multitool location
False - the "New Multitool" window is not displayed. Once
the name has been entered, the multitool will be created
directly in the tool list.
True - a dialog box displaying the buffer, tool magazine and
NC memory is displayed. A mark can be added to or re‐
moved from each of these elements to indicate whether that
element appears in the list display. The "Go to" softkey can
be used to select an element directly in the list display.
False - no dialog box for magazine selection. The system
switches between the buffer, the tool magazines and the
NC memory.
If there is no MagazineSelectionDialog entry in the
<Settings> tag, the dialog box is automatically displayed
with more than one tool magazine (excluding the system
magazine) when magazine configuration is taking place. If
there is only one tool magazine, the switchover function is
used.
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1